mirror of
https://gitlab.isc.org/isc-projects/kea
synced 2025-08-31 22:15:23 +00:00
[1011] move Logging Message Format section after Logging configuration section
This commit is contained in:
@@ -1470,96 +1470,6 @@ then change those defaults with config set Resolver/forward_addresses[0]/address
|
|||||||
<chapter id="logging">
|
<chapter id="logging">
|
||||||
<title>Logging</title>
|
<title>Logging</title>
|
||||||
|
|
||||||
<!-- TODO: how to configure logging, logging destinations etc. -->
|
|
||||||
|
|
||||||
<section>
|
|
||||||
<title>Logging Message Format</title>
|
|
||||||
|
|
||||||
<para>
|
|
||||||
Each message written by BIND 10 to the configured logging
|
|
||||||
destinations comprises a number of components that identify
|
|
||||||
the origin of the message and, if the message indicates
|
|
||||||
a problem, information about the problem that may be
|
|
||||||
useful in fixing it.
|
|
||||||
</para>
|
|
||||||
|
|
||||||
<para>
|
|
||||||
Consider the message below logged to a file:
|
|
||||||
<screen>2011-06-15 13:48:22.034 ERROR [b10-resolver.asiolink]
|
|
||||||
ASIODNS_OPENSOCK error 111 opening TCP socket to 127.0.0.1(53)</screen>
|
|
||||||
</para>
|
|
||||||
|
|
||||||
<para>
|
|
||||||
Note: the layout of messages written to the system logging
|
|
||||||
file (syslog) may be slightly different. This message has
|
|
||||||
been split across two lines here for display reasons; in the
|
|
||||||
logging file, it will appear on one line.)
|
|
||||||
</para>
|
|
||||||
|
|
||||||
<para>
|
|
||||||
The log message comprises a number of components:
|
|
||||||
|
|
||||||
<variablelist>
|
|
||||||
<varlistentry>
|
|
||||||
<term>2011-06-15 13:48:22.034</term>
|
|
||||||
<!-- TODO: timestamp repeated even if using syslog? -->
|
|
||||||
<listitem><para>
|
|
||||||
The date and time at which the message was generated.
|
|
||||||
</para></listitem>
|
|
||||||
</varlistentry>
|
|
||||||
|
|
||||||
<varlistentry>
|
|
||||||
<term>ERROR</term>
|
|
||||||
<listitem><para>
|
|
||||||
The severity of the message.
|
|
||||||
</para></listitem>
|
|
||||||
</varlistentry>
|
|
||||||
|
|
||||||
<varlistentry>
|
|
||||||
<term>[b10-resolver.asiolink]</term>
|
|
||||||
<listitem><para>
|
|
||||||
The source of the message. This comprises two components:
|
|
||||||
the BIND 10 process generating the message (in this
|
|
||||||
case, <command>b10-resolver</command>) and the module
|
|
||||||
within the program from which the message originated
|
|
||||||
(which in the example is the asynchronous I/O link
|
|
||||||
module, asiolink).
|
|
||||||
</para></listitem>
|
|
||||||
</varlistentry>
|
|
||||||
|
|
||||||
<varlistentry>
|
|
||||||
<term>ASIODNS_OPENSOCK</term>
|
|
||||||
<listitem><para>
|
|
||||||
The message identification. Every message in BIND 10
|
|
||||||
has a unique identification, which can be used as an
|
|
||||||
index into the <ulink
|
|
||||||
url="bind10-messages.html"><citetitle>BIND 10 Messages
|
|
||||||
Manual</citetitle></ulink> (<ulink
|
|
||||||
url="http://bind10.isc.org/docs/bind10-messages.html"
|
|
||||||
/>) from which more information can be obtained.
|
|
||||||
</para></listitem>
|
|
||||||
</varlistentry>
|
|
||||||
|
|
||||||
<varlistentry>
|
|
||||||
<term>error 111 opening TCP socket to 127.0.0.1(53)</term>
|
|
||||||
<listitem><para>
|
|
||||||
A brief description of the cause of the problem.
|
|
||||||
Within this text, information relating to the condition
|
|
||||||
that caused the message to be logged will be included.
|
|
||||||
In this example, error number 111 (an operating
|
|
||||||
system-specific error number) was encountered when
|
|
||||||
trying to open a TCP connection to port 53 on the
|
|
||||||
local system (address 127.0.0.1). The next step
|
|
||||||
would be to find out the reason for the failure by
|
|
||||||
consulting your system's documentation to identify
|
|
||||||
what error number 111 means.
|
|
||||||
</para></listitem>
|
|
||||||
</varlistentry>
|
|
||||||
</variablelist>
|
|
||||||
</para>
|
|
||||||
|
|
||||||
</section>
|
|
||||||
|
|
||||||
<section>
|
<section>
|
||||||
<title>Logging configuration</title>
|
<title>Logging configuration</title>
|
||||||
|
|
||||||
@@ -2175,6 +2085,94 @@ Logging/loggers[0]/output_options[0]/maxver 8 integer (modified)
|
|||||||
|
|
||||||
</section>
|
</section>
|
||||||
|
|
||||||
|
<section>
|
||||||
|
<title>Logging Message Format</title>
|
||||||
|
|
||||||
|
<para>
|
||||||
|
Each message written by BIND 10 to the configured logging
|
||||||
|
destinations comprises a number of components that identify
|
||||||
|
the origin of the message and, if the message indicates
|
||||||
|
a problem, information about the problem that may be
|
||||||
|
useful in fixing it.
|
||||||
|
</para>
|
||||||
|
|
||||||
|
<para>
|
||||||
|
Consider the message below logged to a file:
|
||||||
|
<screen>2011-06-15 13:48:22.034 ERROR [b10-resolver.asiolink]
|
||||||
|
ASIODNS_OPENSOCK error 111 opening TCP socket to 127.0.0.1(53)</screen>
|
||||||
|
</para>
|
||||||
|
|
||||||
|
<para>
|
||||||
|
Note: the layout of messages written to the system logging
|
||||||
|
file (syslog) may be slightly different. This message has
|
||||||
|
been split across two lines here for display reasons; in the
|
||||||
|
logging file, it will appear on one line.)
|
||||||
|
</para>
|
||||||
|
|
||||||
|
<para>
|
||||||
|
The log message comprises a number of components:
|
||||||
|
|
||||||
|
<variablelist>
|
||||||
|
<varlistentry>
|
||||||
|
<term>2011-06-15 13:48:22.034</term>
|
||||||
|
<!-- TODO: timestamp repeated even if using syslog? -->
|
||||||
|
<listitem><para>
|
||||||
|
The date and time at which the message was generated.
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term>ERROR</term>
|
||||||
|
<listitem><para>
|
||||||
|
The severity of the message.
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term>[b10-resolver.asiolink]</term>
|
||||||
|
<listitem><para>
|
||||||
|
The source of the message. This comprises two components:
|
||||||
|
the BIND 10 process generating the message (in this
|
||||||
|
case, <command>b10-resolver</command>) and the module
|
||||||
|
within the program from which the message originated
|
||||||
|
(which in the example is the asynchronous I/O link
|
||||||
|
module, asiolink).
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term>ASIODNS_OPENSOCK</term>
|
||||||
|
<listitem><para>
|
||||||
|
The message identification. Every message in BIND 10
|
||||||
|
has a unique identification, which can be used as an
|
||||||
|
index into the <ulink
|
||||||
|
url="bind10-messages.html"><citetitle>BIND 10 Messages
|
||||||
|
Manual</citetitle></ulink> (<ulink
|
||||||
|
url="http://bind10.isc.org/docs/bind10-messages.html"
|
||||||
|
/>) from which more information can be obtained.
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term>error 111 opening TCP socket to 127.0.0.1(53)</term>
|
||||||
|
<listitem><para>
|
||||||
|
A brief description of the cause of the problem.
|
||||||
|
Within this text, information relating to the condition
|
||||||
|
that caused the message to be logged will be included.
|
||||||
|
In this example, error number 111 (an operating
|
||||||
|
system-specific error number) was encountered when
|
||||||
|
trying to open a TCP connection to port 53 on the
|
||||||
|
local system (address 127.0.0.1). The next step
|
||||||
|
would be to find out the reason for the failure by
|
||||||
|
consulting your system's documentation to identify
|
||||||
|
what error number 111 means.
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
</variablelist>
|
||||||
|
</para>
|
||||||
|
|
||||||
|
</section>
|
||||||
|
|
||||||
</chapter>
|
</chapter>
|
||||||
|
|
||||||
<!-- TODO: how to help: run unit tests, join lists, review trac tickets -->
|
<!-- TODO: how to help: run unit tests, join lists, review trac tickets -->
|
||||||
|
Reference in New Issue
Block a user