timeval: Fix seq memory leak
'timewarp_seq' should be initialized only once, while init_clock() is called multiple times (once for each clock instance). Found by valgrind Signed-off-by: Daniele Di Proietto <ddiproietto@vmware.com> Acked-by: Jarno Rajahalme <jrajahalme@nicira.com>
This commit is contained in:
committed by
Jarno Rajahalme
parent
88ace79b3e
commit
33c24cf9f4
@@ -114,7 +114,6 @@ init_clock(struct clock *c, clockid_t id)
|
||||
ovs_mutex_init(&c->mutex);
|
||||
atomic_init(&c->slow_path, false);
|
||||
xclock_gettime(c->id, &c->cache);
|
||||
timewarp_seq = seq_create();
|
||||
memset(&c->large_warp, 0, sizeof(c->large_warp));
|
||||
}
|
||||
|
||||
@@ -125,6 +124,7 @@ do_init_time(void)
|
||||
|
||||
coverage_init();
|
||||
|
||||
timewarp_seq = seq_create();
|
||||
init_clock(&monotonic_clock, (!clock_gettime(CLOCK_MONOTONIC, &ts)
|
||||
? CLOCK_MONOTONIC
|
||||
: CLOCK_REALTIME));
|
||||
|